Known Issues | Q-SYS Designer Software v9.4.5 LTS
Learn about the known issues associated with Q-SYS Designer Software version 9.4.5 LTS.
Audio Peripherals and Components
QIO Error, "Grandmaster mismatch error"
Issue: When wiring the input for QIO, error "grandmaster mismatch error" or "packet missing" error may appear.
Workaround: This issue has been resolved in Q-SYS Designer 9.6.0.4.
Earliest Reported Version: 9.4.0
Version Fixed: 9.7.0 and 9.4.5 LTS. For more information, see the What's New section in Q-SYS Help for v9.7 and the Q-SYS Help for v9.4.
Amplifiers
Custom Voicing High and Low Pass Filters bypassed incorrectly
Issue: High Pass and Low Pass filters in a custom voicing block may display as not bypassed, although they are bypassed. This behavior also occurs when transferring between primary and backup cores.
Workaround: Toggling the bypass button off and on resolves the issue temporarily. However, reloading the design causes all filters to be bypassed again, yet they still show as not bypassed.
Earliest Reported Version: 9.9.0 and 9.4.5 LTS Branch.
Version Fixed: 9.10.0 and 9.4.8 LTS. For more information, see the What's New section in Q-SYS Help for v9.10.0 and the What's New section in Q-SYS Help for v9.4.x.
Loudspeakers
Error updating AD-P.SUB" when changing loudspeaker model"
Issue: If you attempt to update a loudspeaker component's Model property to AD-P.SUB while the component is in the schematic, an error window appears, and the loudspeaker model does not actually change. If you attempt to open the loudspeaker's control panel, Designer closes unexpectedly
Workaround: Either add an AD-P.SUB directly from the Inventory, or update an existing loudspeaker's Model property to AD-P.SUB before dragging the component into the schematic.
Earliest Reported Version: 9.4.0, and affects all versions in the LTS branch.
Version Fixed: 9.8.0 and 9.4.6. For more information, see the What's New section in Q-SYS Help for v9.8 and the What's New section in Q-SYS Help for v9.4.
Video Peripherals and Components
NC-110 Error: “802.1x settings save failed for LAN A”
Issue: NC-110 fails to save the 802.1x configuration. Error: “802.1x settings save failed for LAN A.”
Workaround: Change the certificate format to PEM.
Earliest Reported Version: 9.7.0 and 9.4.4 LTS.
Version Fixed: This issue is under investigation.
NV-32-H: Packet loss when Shift AV and USB Video Bridge are both active on an NV decoder
Issue: Netgear 26G4F M4250 drops packets when Shift AV and USB Video Bridge are both active on an NV decoder.
Workaround: Increase NC camera bitrate to 16 Mbps or higher, decrease Shift AV bitrate to 600Mbps
Earliest Reported Version: 9.6.0 and 9.4.5 LTS.
Version Fixed: This issue is under investigation.
NV-32-H: Does not receive 4K60 video with Intel Iris Xe Graphics
Issue: NV-32-H cannot receive valid 4k60 video with Intel Iris Xe Graphics.
Workaround: None. This will be fixed in an upcoming release.
Earliest Reported Version: 9.8.1 and 9.4.5 LTS.
Version Fixed: This issue is under investigation.
NV-32-H (Core Capable): Fault error, "event_base_manager blocked"
Issue: Under certain circumstances, the Event Log for an NV-32-H (Core Capable) design might indicate "event_base_manager blocked", followed by the Core becoming unresponsive after a period of time.
Workaround: Reboot the NV-32-H (Core Capable).
Earliest Reported Version: 9.3.1, which affects all versions of the LTS Branch.
Version Fixed: This issue is under investigation.
NV-32-H: Multicast Shift AV intermittent Packet Loss on LAN A when switching AV streams
Issue: The NV-32-H Shift AV may experience occasional audio packet loss in LAN A when switching between AV streams. This might cause intermittent disruptions in the audio transmission.
Workaround: None. This will be resolved in an upcoming release.
Earliest Reported Version: 9.1, which affects all versions in the LTS branch.
Version Fixed: This issue is under investigation.
NV-32-H: HDMI output stops working after switching HDMI I/O Device Type: Encoder to/from Decoder
Issue: If you change the HDMI I/O component Device Type property from Encoder to Decoder or vice versa and then redeploy the design, HDMI output may stop working.
Workaround: In rare cases, the affected NV-32-H unit may require a power cycle after changing Encoder / Decoder modes. Unplug the NV-32-H from power for a few seconds and then plug it back in.
Earliest Reported Version: 8.2, which includes all versions of the LTS Branch.
Version Fixed: This issue is under investigation.
Control Peripherals and Components
UCI Toolbox
Issue: Some controls within a State Trigger Button and/or ComboBox within a UCI Toolbox cannot be activated when accessing the UCI from a physical TSC, Windows UCIViewer Application, or a mobile device (Android and iPhone accessing WebUCI).
Workaround: Utilize traditional, non-Toolbox methods for State Trigger Button and ComboBox objects.
Earliest Reported Version: 9.5.0 and 9.4.3 LTS. This has not yet been resolved in the LTS (9.4.x branch).
Version Fixed: 9.12.0. For more information, see the What's New section in Q-SYS Help for v9.12.0.
UCI Toolbox
Issue: Some controls within a State Trigger Button and/or ComboBox within a UCI Toolbox cannot be activated when accessing the UCI from a physical TSC, Windows UCIViewer Application, or a mobile device (Android and iPhone accessing WebUCI).
Workaround: Utilize traditional, non-Toolbox methods for State Trigger Button and ComboBox objects.
Earliest Reported Version: 9.5.0 and 9.4.3 LTS.
Version Fixed: WebUCI was fixed in 9.10; however UCIViewer and TSC's are still under investigation.
Camera Status Block cannot be added or removed from a Container
Issue: When a Camera is added to a design, moving it into a Container from another part of a design returns it to the Inventory. If it is placed directly into a Container and removed from the Container, it also returns to the Inventory.
Workaround: Either place the Camera directly into the Inventory or place the Camera Status Block where you want it in the design.
Earliest Reported Version: 9.9.0 and 9.4.5 LTS.
Version Fixed: 9.12.0. For more information, see the What's New section in Q-SYS Help for v9.12.0. This has not yet been resolved for the LTS (9.4.x) branch.
UCI Variable styles are applied for all
Issue: With UCI’s that share the same CSS all change visual style when a single UCI changes style dynamically.
Workaround: Having multiple CSS copies for every UCI will prevent this from occurring.
Earliest Reported Version: 9.8.0 and 9.4.4 LTS.
Version Fixed: 9.9. For more information, see the What's New section in Q-SYS Help for v9.9. This has not yet been resolved in the (9.4.x) LTS branch.
UCI Style Controller custom font styles are not applied properly for the Controls & Tools
Issue: Custom Font Styles are not applied properly for the Controls & Tools via UCI Style Controller.
Workaround: Specify different font-family names for your imported @font-faces.
Earliest Reported Version: 9.8.2 and 9.4.5 LTS Branch.
Version Fixed: This issue is under investigation.
Polling SNMP OID's with Text Controller stops updating if the IP of the Target Agent changes in QDS
Issue: After changing a Target Agent IP in QDS, swapping between two identical Agents that are polling with the same SNMP OID address my stop polling.
Workaround: Restarting the script will fix this.
Earliest Reported Version: 9.6.0 and 9.4.3 LTS.
Version Fixed: 9.8 and 9.4.6. For more information, see the What's New section in Q-SYS Help for v9.8 and the What's New section in Q-SYS Help for v9.4.
Call Sync not disabled with vCore
Issue: If a design schematic contains a Call Sync component and the Core Model is changed to 'vCore Control', the Call Sync component remains enabled while any wired Call Systems or Endpoints become properly disabled (grayed out).
Workaround: None. Call Sync is not supported with vCore despite not showing as disabled in designs that use vCore.
Earliest Reported Version: 9.6.0 and 9.4.4 LTS Branch.
Version Fixed: This issue is under investigation.
SNMP OID Read Values truncated at 100 character
Issue: In the SNMP Query component, the Read Value for a queried OID is truncated at 100 characters.
Workaround: None. This is a current limitation that is planned to be addressed in a future release.
Earliest Reported Version: 9.4.4 LTS and 9.6.0.
Version Fixed: 9.8.0 and 9.4.6 LTS. For more information, see the What's New section in Q-SYS Help for v9.8 and the What's New section in Q-SYS Help for v9.4.
Streaming I/O
System Link streams do not resume after forcing Primary Core to Active
Issue: In a Core-redundant configuration, after forcing a Backup Core to Active status and then forcing the Primary Core back to Active, System Link AV and audio streams do not resume as expected.
Workaround: Redeploy the design to the Primary Core. This will be fixed in an upcoming release.
Earliest Reported Version: 9.4.2 and 9.6.0.
Version Fixed: 9.7.0. For more information, see the What's New section in Q-SYS Help for v9.7. This has not yet been resolved in the (9.4.x) LTS branch.
Platform
Core 110f with Software Dante not showing in Dante Controller
Issue: A Core with Software Dante deployed that was previously enrolled in a Dante Domain may not be discoverable in Dante Controller if the Core was not properly un-enrolled from the Domain.
Workaround: Delete the DDM.conf and UUID files.
- Disconnect Windows the Core from the Design
- Run the Design in Emulation Mode
- Open the Windows Explorer Folder and navigate to C:\Users\qsc\AppData\Local\Temp\QSys Temp Files
- Open the most recent hash folder (For example, C:\Users\username\AppData\Local\Temp\QSys Temp Files\638360882256976981) and open the Settings Folder
- Delete “DDM.conf” and "UUID" files
- Save the Design while still in Emulation Mode
- Disconnect Emulation Mode
- Save to the Core & Run
- Open Dante Controller to verify that Software Dante components now show
Earliest Reported Version: 9.9.1 and 9.4.5 LTS.
Version Fixed: This issues has been resolved in v9.4.7 (LTS). For more information, see the What's New section in Q-SYS Help for v9.4. It has not yet been resolved in the mainline version.
PA Router plays all input sources when Virtual Page station is playing a message
Issue: In designs using Virtual Page Stations, the PA router will play all the input sources when the Virtual Page station is playing a message.
Workaround: None. This will be addressed in a future release.
Earliest Reported Version: 9.6.0 and 9.4.5 LTS
Version Fixed: 9.8.0 and 9.4.6 LTS. For more information, see the What's New section in Q-SYS Help for v9.8 and the What's New section in Q-SYS Help for v9.4.
Management
Unable to sign CSR: "Invalid certificate" error when attempting to enable 802.1X
Issue: For some Q-SYS peripherals, including QIO Series, NC-110, and NL Series, you may encounter errors when either attempting to sign a certificate (CSR request) or enable 802.1X:
- QIO Series: Attempting to sign a CSR in MS Active Directory using Cisco ISE results in a "Certificate Request Denied" error.
- NC-110, NL Series: Attempting to upload a CA Certificate in Peripheral Manager and enable 802.1X results in an "Invalid certificate" error.
Workaround: None at this time. The issue is being investigated.
Earliest Reported Version: 9.7.0 and 9.4.5 LTS Branch.
Version Fixed: 9.9.0 and 9.4.6 LTS. For more information, see the What's New section in Q-SYS Help for v9.9 and the What's New section in Q-SYS Help for v9.4.
Reflect Redundant Core shows Inventory as "Unavailable"
Issue: In a redundant Core configuration, after upgrading the Core firmware, the Reflect > Sites > Systems > Status page may show "Unavailable" in the Inventory section.
Workaround: Reboot the Cores and refresh the Status page in your browser.
Earliest Reported Version: 9.3, and it affects all versions in the LTS Branch.
Version Fixed: This issue is under investigation.
Reflect '+ Add Core' button disabled on Sites > Systems page
Issue: When attempting to add another Core to a Site, such as when adding the second of two Cores in a redundant pair System, the + Add Core button is grayed out.
Workaround: None. Currently, the maximum number of Cores that can be registered to your Organization equals the number of System licenses enabled on the Organization, regardless of whether a System is redundant. This will be fixed in a future update. Note that the Subscription Details table on the Organizations page correctly shows the number of connected Systems and does not represent the number of connected Cores when using any Redundant Core systems.
Earliest Reported Version: 9.3, and it affects all versions of the LTS Branch.
Version Fixed: This issue is under investigation.