Procedure


For more in-depth details and setup please check out Audio-Technica Online Manual located here

  1. Before you can setup the microphone, the ATND1061DAN must be connected to a network and have a valid IP address on the same subnet as the Q-SYS system being connected to.
    1. The IP address can be obtained or configured from Digital Microphone Manager, Audio-Technica software application for the ATND1061DAN.
  2. Launch a web browser to control the device.
  3. Enter the IP address of the microphone for which Web Remote will be launched.
    1. Once Web Remote is launched, the Setting & Maintenance screen will appear.

  1. Navigate to the System Settings - > Network Tab on the left hand side of the screen.
  2. Ensure that the follow settings are enabled in order to be able to communicate with the Q-SYS plugin and Microsoft Teams Room Sample Design:
    1. Notifications
    2. Audio Level Notifications
    3. Camera Control Notifications
    4. Port Number: 17300
    5. Multicast Port Number: 17000

  1. After you enable these features select the Apply button in the bottom right corner and reboot the microphone.

For plugin configuration please see the plugin help file located in Q-SYS Asset Manager or click here.